There are 673 products.

Showing 577-588 of 673 item(s)

Active filters

Three-phase asymmetry and sequence monitors CKF-319 True RMS

CKF-320-TRMS, 5902431674391

To protect electric motors supplied from a three-phase network in the event of a power failure in at least one phase or voltage unbalance between phases that threatens to destroy the motor and to protect the direction of rotation of the motor in the event of a phase change in front of the sensor.

Voltage indicator WN-711S

WN-711S, 5902431671062

Led line type. One phase indicator. With indication triggering.
Voltage indicator WN-711S is used for continuous measurement the value of the voltage in a single-phase or three-phase network.

TI-125-5 current transformer

TI-125-5, 5902431675237


Single-phase current transformer
with closed core
Ratio 125/5.
Power 2.5 VA.


The current transformer is used to proportionally change large current intensities to lower values, adapted to the measuring ranges of control and measuring equipment.

Current transformer TI-500-5

TI-500-5, 5902431675244


Single-phase current transformer
withclosed core
Ratio 500/5.
Power 2.5 VA.


The current transformer is used to proportionally change large current intensities to lower values, adapted to the measuring ranges of control and measuring equipment.

MST-03 inrush current limiter for 230 V AC circuits

MST-03, 5902431674384
MST-03 is designed to limit current overcurrents occurring when switching on the power supply of circuits with inductive or capacitive characteristics (such as LED lighting, pulse power supplies, lighting fixtures) or non-linear characteristics (such as incandescent and halogen lamps).

Three-phase asymmetry and sequence monitors CKF-319 True RMS

CKF-320-TRMS, 5902431674391

To protect electric motors supplied from a three-phase network in the event of a power failure in at least one phase or voltage unbalance between phases that threatens to destroy the motor and to protect the direction of rotation of the motor in the event of a phase change in front of the sensor.

TI-125-5 current transformer

TI-125-5, 5902431675237


Single-phase current transformer
with closed core
Ratio 125/5.
Power 2.5 VA.


The current transformer is used to proportionally change large current intensities to lower values, adapted to the measuring ranges of control and measuring equipment.

Current transformer TI-500-5

TI-500-5, 5902431675244


Single-phase current transformer
withclosed core
Ratio 500/5.
Power 2.5 VA.


The current transformer is used to proportionally change large current intensities to lower values, adapted to the measuring ranges of control and measuring equipment.

MST-03 inrush current limiter for 230 V AC circuits

MST-03, 5902431674384
MST-03 is designed to limit current overcurrents occurring when switching on the power supply of circuits with inductive or capacitive characteristics (such as LED lighting, pulse power supplies, lighting fixtures) or non-linear characteristics (such as incandescent and halogen lamps).