Pulse meter CLI-11T 24 V

Panel. 110 ÷ 240 V AC/DC
Pulse meters are intended for counting AC/DC voltage signals, generated by additional peripheral devices in order to determine the number of carried out working cycles in automatics systems, e.g. in order to control the number of press strokes, the number of revolutions of a rotating device, the number of components leaving the production line, etc.

Pulse counter MB-LI-4 Hi

Pulse counter four-channel with MODBUS RTU output.
The pulse counter is used for counting the AC/DC signals generated by external devices to determine the number of completed work cycles and for exchanging the data via RS-485 port in accordance with the MODBUS RTU protocol.

Working time meter CLG-13T 24 V

Electronic one-way meter.
Working time meters are intended for counting the number of working hours in automatic production processes or the number of device working hours, which, due to safety requirements and operation efficiency have limited overhaul life, i.e operational capacity that may not be exceeded (e.g. advanced power units, special radioactive lamps, etc.).

Voltage relays CP-721

Single phase. Programmable.
The CP-721 voltage relay is used to control the single-phase voltage and to protect the single-phase load from the effects of voltage increase or decrease outside the set values.

Working time meter MB-LG-4 Hi

Operating time counter four-channel with MODBUS RTU output.
The MB-LG-4 counter is a four-channel, one-way operating time counter with implemented function to exchange the registered data via RS-485 port in accordance with the MODBUS RTU protocol.

Power consumption limiters OM-633

Power 1-10kW.
The power consumption limiter OM-633 is used to automatically disconnect the power supply circuit of the electrical installation in the event of exceeding the determined value of power consumed by receivers in this circuit and to control the supply voltage of this receiver and protect it from the effects of voltage rise or fall outside the set values.

Temperature regulator RT-823

For general use. Temperature range 60÷95 °C.
Temperature regulators may be used for equipment control in anti-freeze systems which prevent the freezing of gutters, the accumulation of ice on stairs, vehicles, etc.

Current transducer MB-1I-1 15A

With output MODBUS RTU. Single-phase 15 A AC/20 A DC. Direct.
MB-1I-1 transducer is designed to measure the strength of alternating current and direct current and to transmit the data via RS-485 port using MODBUS RTU protocol.

Current transducer MB-3I-1 15A

3F current transducer with MODBUS RTU output. Three-phase 15 A AC/20 A DC. Direct.
MB-3I-1 transducer is designed to measure the strength of alternating current or direct current and to transmit the data via RS-485 port using MODBUS RTU protocol.

Pulse power supply ZI-22

Output voltage 12 V. Power 30 W.
The switched-mode power supply is used to supply electric and electronic devices that require a stable, filtered supply voltage independent of changes in the mains voltage.

Digital inputs expansion MR-DI-4 Lo

With MODBUS RTU output.
The MR-DI-4 module is used as an external device that extends digital inputs of the PLC programmable controllers or other devices in which data is exchanged via the RS-485 port with MODBUS RTU protocol.

Pulse meter CLI-11T 24 V

CLI-11T-24V, 5908312591856
Panel. 110 ÷ 240 V AC/DC
Pulse meters are intended for counting AC/DC voltage signals, generated by additional peripheral devices in order to determine the number of carried out working cycles in automatics systems, e.g. in order to control the number of press strokes, the number of revolutions of a rotating device, the number of components leaving the production line, etc.

Pulse counter MB-LI-4 Hi

MAX-MB-LI-4 HI, 5908312598336
Pulse counter four-channel with MODBUS RTU output.
The pulse counter is used for counting the AC/DC signals generated by external devices to determine the number of completed work cycles and for exchanging the data via RS-485 port in accordance with the MODBUS RTU protocol.

Working time meter CLG-13T 24 V

CLG-13T-24V, 5908312591870
Electronic one-way meter.
Working time meters are intended for counting the number of working hours in automatic production processes or the number of device working hours, which, due to safety requirements and operation efficiency have limited overhaul life, i.e operational capacity that may not be exceeded (e.g. advanced power units, special radioactive lamps, etc.).

Working time meter MB-LG-4 Hi

MAX-MB-LG-4 HI, 5908312598466
Operating time counter four-channel with MODBUS RTU output.
The MB-LG-4 counter is a four-channel, one-way operating time counter with implemented function to exchange the registered data via RS-485 port in accordance with the MODBUS RTU protocol.

Power consumption limiters OM-633

OM-633, 5908312597247
Power 1-10kW.
The power consumption limiter OM-633 is used to automatically disconnect the power supply circuit of the electrical installation in the event of exceeding the determined value of power consumed by receivers in this circuit and to control the supply voltage of this receiver and protect it from the effects of voltage rise or fall outside the set values.