Electronic bistable impulse relay BIS-412M 4 V
Power supply 9÷30 V AC/DC. Maximum load 16 A. On rail TH-35. With the memory of the contact position. Can be used with backlit buttons.
Functioning:
Local control
The receiver is activated after a current pulse that is triggered by pushing one optional momentary push-button belonging to the local control group. The contact of the relay is switched to the 7-10 position. After a next current pulse, the receiver will be deactivated (the contact of the relay returns to the 7-12 position).
Central control
DEACTIVATE ALL - after a current pulse triggered by pushing the momentary push-button , all receivers will be deactivated (regardless of their status, i.e. deactivation or activation) that are controlled separately by individual relays. The contact in each relay will be switched to the 7-12 position.
ACTIVATE ALL - after a current pulse triggered by pushing the momentary push-button , all receivers will be activated (regardless of their status, i.e. deactivation or activation) that are controlled separately by individual relays. The contact in each relay will be switched to the 7-10 position.
Attention!
BIS-412M 24V is not compatible with backlit buttons.
- Power supply voltage
- 9÷30 V AC/DC
- Local control
- YES
- Maximum AC-1 load current
- 16 A
- The executive element
- relay
- Contact configuration
- 1 × NO/NC
- Separation of the contact
- YES
- Resistance to shock currents
- NO
- Number of channels
- 1
- functionality
- group (hotel)
- Delay of operation
- 0,1 ÷ 0,2 s
- Control pulse current
- less than 5 mA
- Cooperation with illuminated buttons
- NO
- Status memory after power failure
- YES
- Activate on time
- NO
- Dedicated central control inputs
- YES
- Radio control
- NO
- Terminal
- pluggable terminal blocks 2,5 mm²
- Tightening torque
- 0,4 Nm
- Power consumption
- 0,7 W
- Working temperature
- -25 ÷ 50 °C
- Dimensions
- 1 module (18 mm)
- Assembly
- on rail 35 mm
- Ingress Protection Marking
- IP20
Z uwagi na niskie napięcie zasilania nie należy stosować przycisków podświetlanych.
Maksymalny prąd obciążenia
Prąd styku podany w danych technicznych jest wartością maksymalną i może podlegać ograniczeniom – więcej informacji. Jeśli z przedstawionych informacji wynika, że przekaźnik w urządzeniu jest niewystarczający zaleca się stosować zewnętrzny element przełączający (np. stycznik) przystosowany do przełączania dużych prądów udarowych.
Pamięć stanu
Wersja przekaźnika z literą "M" posiada pamięć pozycji styku, tzn. po załączeniu zasilania zostanie przywrócony stan przekaźnika jaki był w momencie wyłączenia zasilania.