Electronic bistable impulse relay BIS-408

BIS-408, 5908312598282
Electronic bistable impulse relay allows switching of lighting or other equipment from several different points of using the control buttons are connected in parallel.
Power supply 230 V AC. Maximum load 16 A. To under plaster box Ø60. Can be used with backlit buttons.

Functioning
The receiver is after the current pulse caused by pressing any (bell) connected to the relay. Exclusion the receiver will be the next pulse.
The relay does not have a "memory" of the contact position, ie. in the case of power failure and the subsequent return, contact the relay will be set in the off.
This prevents the automatic switching of loads without supervision after a prolonged power failure.
 

Note!
BIS-408 and BIS-408i can be used with backlit buttons.    

Power table


 

The above data are indicative and will depend to a large extent on the design of a specific receiver (especially for LED bulbs, energy saving lamps, electronic transformers and pulse power supplies), switching frequency and working conditions.

BIS-408
Power supply voltage
165÷265 V AC
Local control
YES
Maximum AC-1 load current
16 A
The executive element
relay
Contact configuration
1 × NO
Separation of the contact
NO
Resistance to shock currents
NO
Number of channels
1
functionality
ON/OFF
Delay of operation
0,1 ÷ 0,2 s
Control pulse current
less than 5 mA
Cooperation with illuminated buttons
YES
Status memory after power failure
NO
Activate on time
NO
Dedicated central control inputs
NO
Radio control
NO
Terminal
pluggable terminal blocks 2,5 mm²
Tightening torque
0,4 Nm
Power consumption
0,7 W
Working temperature
-25 ÷ 50 °C
Dimensions
Ø54 (48×43 mm), height: 20 mm
Assembly
in a flush-mounted box Ø60
Ingress Protection Marking
IP20
Przyciski podświetlane
W przypadku podłączenia zbyt dużej ilości przycisków podświetlanych może dochodzić do samoistnego załączania oświetlenia lub załączenia oświetlenia na stałe

Maksymalny prąd obciążenia
Prąd styku podany w danych technicznych jest wartością maksymalną i może podlegać ograniczeniom – więcej informacji. Jeśli z przedstawionych informacji wynika, że przekaźnik w urządzeniu jest niewystarczający zaleca się stosować zewnętrzny element przełączający (np. stycznik) przystosowany do przełączania dużych prądów udarowych.