Electronic bistable impulse relay BIS-412M-LED- 230 V
Relay version "i" is to pin adapted to cooperate with the receivers with high starting current, such as LED fluorescent lamps, ESL fluorescent lamps, electronic transformers, discharge lamps, etc.
Power supply 230 V AC. Maximum load 16 A (160 A/20 ms). On rail TH-35. With the memory of the contact position. Can be used with backlit buttons.
Functioning:
Local control
The receiver is activated after a current pulse that is triggered by pushing one optional momentary push-button belonging to the local control group. The contact of the relay is switched to the 7-10 position. After a next current pulse, the receiver will be deactivated (the contact of the relay returns to the 7-12 position).
Central control
DEACTIVATE ALL - after a current pulse triggered by pushing the momentary push-button , all receivers will be deactivated (regardless of their status, i.e. deactivation or activation) that are controlled separately by individual relays. The contact in each relay will be switched to the 7-12 position.
ACTIVATE ALL - after a current pulse triggered by pushing the momentary push-button , all receivers will be activated (regardless of their status, i.e. deactivation or activation) that are controlled separately by individual relays. The contact in each relay will be switched to the 7-10 position.
Attention!
The BIS-412 230V is compatible with bell pushes equipped with fluorescent lamps.
- Power supply voltage
- 165÷265 V AC
- Local control
- YES
- Maximum AC-1 load current
- 16 A (120 A/20 ms)
- The executive element
- relay
- Contact configuration
- 1 × NO
- Separation of the contact
- YES
- Resistance to shock currents
- YES
- Number of channels
- 1
- functionality
- group (hotel)
- Delay of operation
- 0,1 ÷ 0,2 s
- Control pulse current
- less than 5 mA
- Cooperation with illuminated buttons
- YES
- Status memory after power failure
- YES
- Activate on time
- NO
- Dedicated central control inputs
- YES
- Radio control
- NO
- Terminal
- pluggable terminal blocks 2,5 mm²
- Tightening torque
- 0,4 Nm
- Power consumption
- 0,7 W
- Working temperature
- -25 ÷ 50 °C
- Dimensions
- 1 module (18 mm)
- Assembly
- on rail 35 mm
- Ingress Protection Marking
- IP20
Z uwagi na niskie napięcie zasilania nie należy stosować przycisków podświetlanych.
Maksymalny prąd obciążenia
Prąd styku podany w danych technicznych jest wartością maksymalną i może podlegać ograniczeniom – więcej informacji. Jeśli z przedstawionych informacji wynika, że przekaźnik w urządzeniu jest niewystarczający zaleca się stosować zewnętrzny element przełączający (np. stycznik) przystosowany do przełączania dużych prądów udarowych.
Pamięć stanu
Wersja przekaźnika z literą "M" posiada pamięć pozycji styku, tzn. po załączeniu zasilania zostanie przywrócony stan przekaźnika jaki był w momencie wyłączenia zasilania..
Odporność na prądy udarowe
W urządzeniu zastosowany został przekaźnik typu "inrush" charakteryzujący się dużą wytrzymałością na krótkotrwałe prądy udarowe powstające np. w momencie załączenia lamp LED, świetlówek ESL, tranformatorów elektronicznych, lamp wyładowczych itp.