Electronic bi-stable pulse relays BIS-414i 230V enables the user to actuate lighting or other devices from various locations by means of control buttons in parallel connection.
Single function. Power supply 230 V AC. Maximum load 2  x 16 A (160 A/20 ms). On TH-35 mm rail. Can be used with backlit buttons.


The relay have got two switch ON section and enable to switch ON in accordance sequence two circuits of lights or diferent recuiver from many places by pushbuttons connected in parallel. Switching the relay into another cycle phase is made by another current pulse triggered by pressing any bell push connected to the relay.
 

Functioning
Relay power is indicated by a green LED U. Sequential relay has two separate outputs: R1 and R2. Contact state (open/closed) is forced sequentially in accordance with a predetermined program. State of contact is switched by a subsequent impulse from the the control key. Switching of R1 and R2 contacts is indicated by the corresponding R1 and R2 red LEDs. In case of a power failure, the contact state is reset. When the supply voltage returns, relay starts with a sequence number 0.
 


 

 
 

Attention!
The BIS-414 230V and  BIS-414i 230V are compatible with bell pushes equipped with fluorescent lamps.    
Power of receivers





These data are indicative and will heavily depend on the design of a specific receiver (that is especially important for LED bulbs, energy-saving lamps, electronic transformers and pulse power supply units), switching frequency and operating conditions.

 

BIS-414-LED
Power supply voltage
165÷265 V AC
Local control
YES
Maximum AC-1 load current
2 x16 A (120 A/20 ms)
The executive element
relay
Contact configuration
2 × NO
Separation of the contact
YES
Resistance to shock currents
YES
Number of channels
2
functionality
candlestick
Delay of operation
0,1 ÷ 0,2 s
Control pulse current
less than 5 mA
Cooperation with illuminated buttons
YES
Status memory after power failure
NO
Activate on time
NO
Dedicated central control inputs
NO
Radio control
NO
Terminal
pluggable terminal blocks 2,5 mm²
Tightening torque
0,4 Nm
Power consumption
0,7 W
Working temperature
-25 ÷ 50 °C
Dimensions
1 module (18 mm)
Assembly
on rail 35 mm
Ingress Protection Marking
IP20


Przyciski podświetlane
W przypadku podłączenia zbyt dużej ilości przycisków podświetlanych może dochodzić do samoistnego załączania oświetlenia lub załączenia oświetlenia na stałe

Maksymalny prąd obciążenia
Prąd styku podany w danych technicznych jest wartością maksymalną i może podlegać ograniczeniom – więcej informacji. Jeśli z przedstawionych informacji wynika, że przekaźnik w urządzeniu jest niewystarczający zaleca się stosować zewnętrzny element przełączający (np. stycznik) przystosowany do przełączania dużych prądów udarowych.


Pamięć stanu
Przekaźnik nie posiada "pamięci" pozycji styku. Oznacza to, że po załączeniu zasilania styk przekaźnika zawsze pozostanie w stanie wyłączonym.

Odporność na prądy udarowe
W urządzeniu zastosowany został przekaźnik typu "inrush" charakteryzujący się dużą wytrzymałością na krótkotrwałe prądy udarowe powstające np. w momencie załączenia lamp LED, świetlówek ESL, tranformatorów elektronicznych, lamp wyładowczych itp.