Fluid level control relay PZ-829 RC-WD
search
  • Fluid level control relay PZ-829 RC-WD
  • Fluid level control relay PZ-829 RC-WD
  • Fluid level control relay PZ-829 RC-WD
  • Fluid level control relay PZ-829 RC-WD
  • Fluid level control relay PZ-829 RC-WD

Fluid level control relay PZ-829 RC-WD

PZ-829RC-WD, 5902431675169

For demineralized water.
Two-position. Adjustable sensitivity.
Fluid level control relays  are devised to detect the presence of conductive liquids reaching the level of the sensor.
Allow states to maintain minimum and maximum control in the field of fluid specified by the user.


  
 

Functioning
After the liquid level decreases to MIN (i.e. electrodes MIN and COM spaced), the RMIN contact is switched to position 11-12, whereas the RMAX contact remains in position 8-9. On the other hand, when the MAX liquid level is reached (MAX and COM electrodes shorted), the relay's RMIN contact will be switched to position 11-10, whereas the RMAX into position 8-7.
  

How to connect the probe
The electrode probe is connected by means of a cable with wire diameter up to 1 mm and maximum length of 100 m.
  

Attention!
output 4-5-6 galvanic separated
  

PZ-829RC-WD
Power supply voltage
230 V AC
The executive element
2 × relay
Maximum load current
2 × 16 A
Contact configuration
2 × NO/NC
Separation of the contact
YES
Sensitivity - adjustable
1÷820 kΩ
Współpraca z wodą deszczową
TAK
Voltage of measuring outputs
6 V
Type of flood probe
3 x PZ2
Switching delay for the MIN point
1÷2 s
Delay of contact switching for the MAX point
max. 5 s
Probe clamps
separated from the transformer network
Terminal
pluggable terminal blocks 4,0 mm²
Tightening torque
0,5 Nm
Power consumption
1,1 W
Working temperature
-25 ÷ 50 °C
Dimensions
3 modules (52,5 mm)
Assembly
on rail 35 mm
Ingress Protection Marking
IP20